Voltage measurement
(true R.M.S.) Line-to-neutral 20...500 V~ Line-to-line
20...866 V~ Consumption 8 VA
Measuring
range / Ammeter clamp in use 20...2000 A~
(scale 2000 A) / CP-2000-200 2...200 A~ (scale
200 A) / CP-2000-200 10...1000 A~ / CPR-1000 5...500 A~
/ CPR-500 2...200 A~ / CP-200 1...100 A~/
CP-100 50 mA to 5 A~ /
CP-5 5A...20 kA~/ C-Flex Crest factor:
1,75 Frequency 45...65 Hz
Power
supply voltage 230 V~
Voltage
tolerance ± 15 %
Internal power supply Batery:
12 V
Operation autonomy with battery Max.:
8 h
Analyzer functions Program:
energy/harmonics Optional: flicker, disturbances,
check meter and fast check
Basic measurable
parameters Voltage, current, active power, reactive
power, energy, V and A harmonics, flicker, disturbances
and quality of the distribution system, real-time clock,
average, max. and min. values of all parameters.
Accuracy
(5 °C to 45 °C) Voltage: 0,5 % of scale Current:
0,5 % of scale Powers: 1 % of scale (Error due
to ammeter clamps, not included)
Display Graphic
160x160 pixels / Auto-OFF for inner battery saving
Record
and data retrieval from PC Data storage capacity:
1 Mbyte Reacording period: Programmable 5
s ... 4 h (harmonics) 1 s ... 4 h (energy) Optional
trigger conditions by limit values
|
Software for PC Power-VISUAL
Environmental
conditions Limit temperatures: 0 °C / ± 50 °C Relative
humidity: Max. 85 % no condensation
Standards EN
61010 cat. III (Safety), IEC 60664, VDE 0110, UL 94,
EN 60801, EN 50081-1, EN 50082-1, EN 61000-4-15.
Accessories Cables,
Power supply set, Software Power-Vision and RS-232 interface
Ammeters
clamps avaiable CP-2000/200 Clamp 2000/200A CPR-1000
Clamp 1000A CPR-500 Clamp 500A CP-100 (M1-u)
Clamp 100A CP-5 Clamp 5A CP-FLEX2000/200-45. single-phase
(Length 45cm) CP-FLEX 2000/200-80. single-phase (Length
80cm) CP-FLEX 10k/1k-120. single-phase (Length 120cm)
Programs ENERGY:
Basic program that permits to measure voltages, currents,
powers and energies from any phase and to save in memory
the results over regularly recording periods.
HARMONIC: The program for harmonic measurement includes
all the functions that the standard program offers,
but also these functions related to the harmonic measurement
according to the harmonized standards IEC 61000-4-7.
FLICKER (OPTIONAL): The program for Flicker
measurement includes all the functions that the standard
program offers, but also these functions related to
the measurement of voltage fluctuations, so delivering
Pst and Plt, values required according to the harmonized
Standard IEC- 61.000-4-15.
DISTURBANCES (OPTIONAL):
The program for disturbances measurement program permits
to detect and record short or longtime voltage changes
in form of spikes, dips, short-interruptions, sags,
... in dependence on preset limits.
FAST CHECK
(OPTIONAL): This program has been designed for to make
easy the capture of the short duration transients (starting
motors and so on) obtaining registers of all of the
cycles or averages from some of them.
CHECK METER
(OPTIONAL): This program is specially designed to permit
checking actions over energy counters, either for active
or reactive energy.
|