:: home > megohmmeters > medium voltage > max. voltage 5 kV
MD-5060x - TECHNICAL SPECIFICATIONS

Test voltages (T.V.)
500, 1.000, 2.500, 5.000 V directly, one button selectable. 500 V to 5 kV in 100 V steps. DC, negative.

Maximum resistance reading
5 TΩ @ 5kV.

Short circuit current
1,5  ± 0,5 mA

Test voltages accuracy
± 3% of nominal test voltages on R >/= 10 GΩ

Megohmmeter basic accuracy
± 5% of reading ± 3 digits
(1 MΩ to 500 GΩ at any test voltage)

Advanced features
Automated Polarization Index computing
Automated Dielectric Absorption Ratio computing
Pass-fail test / Programmable timer
Step voltage test
Memory for 4000 readings
Real time clock and calendar

Built-in printer
Prints elapsed time, actual voltage and resistance measured each 5 seconds.

Built-in memory

Stores up to 4000 insulation measurements.

Interface
USB.

Built-in chronometer
Shows elapsed time in mm:ss format. Count starts automatically for each measurement.

MegaLogg2 Software
Friendly, easy to use software. Tests are represented in graph and tabular views. With automatic report generator, including the operator´s commentaries.

Environmental protection
IP54 with closed lid.

P 11012111

Safety class
In accordance with IEC 61010-1

E.M.C
In accordance with IEC 61326-1

Electrostatic immunity

In accordance with IEC 61000-4-2

Electro magnetic irradiation immunity
In accordance with IEC 61000-4-3

Power supply
Internal rechargeable 12 V -  2,3 Ah battery

Battery charger
For 100 - 240 V~  mains

Operating temperature range
-5°C to 50°C

Storage temperature range
-25°C to 65°C

Humidity range

95% RH (non condensing)

Weight
Approx. 3.6 kg

Dimensions
274 x 250 x 124 mm

Included accessories
• 3 Measuring test leads 1,80 m.
• 1 GUARD test lead, 1,80 m.
• 1 Charger power cord.
• 1 USB Cable.
• 1 MegaLogg2 software.
• 1 User guide.
• 1 Carrying bag.


CE mark