Four test voltages
(T.V.) 0,5 kV - 1 kV - 2,5 kV
- 5 kV
Maximum resistance reading 1 TΩ
@ 0,5 kV (T.V.) 2 TΩ @ 1 kV
(T.V.) 5 TΩ @ 2,5 kV (T.V.) 10 TΩ
@ 5 kV (T.V.)
Short circuit current 1 mA
± 2 %
Test voltages accuracy ±2% of
nominal test voltages on R ³ 1 GΩ
Megohmmeter
accuracy class 2 (± 2 % of full scale deflection)
Internal
current limiting resistance 500 KΩ @ 0,5 kV
(T.V.) 1 MΩ @ 1 kV (T.V.) 2,5 MΩ @ 2,5 kV (T.V.) 5 MΩ @ 5 kV (T.V.)
Analogue
indicator up to 99mm scale length, taut band, with
mirror (thus avoiding parallax errors)
Environmental
protection IP54 with closed lid.
Safety class In accordance
with IEC 61010-1.
E.M.C In accordance with IEC 61326-1
and 61000-4-3.
|
Electrostatic immunity In
accordance with IEC 61000-4-2.
Power supply Internal
rechargeable 12 V 2.3 Ah, sealed lead acid battery
Battery
charger 100-240 V~ mains supply
Operating
temperature range -5°C to 50°C
Storage
temperature range -25°C to 65°C
Humidity
range 95% RH (non condensing)
Altitude maximum 2000m
Weight Approx.
4,1kg
Dimensions 274
x 250 x 124 mm
Included accessories •
Measuring test leads, 1,80 m. (2) • GUARD test lead,
1,80 m. • Protective case. • Charger power cord. • Operating instructions
CE
mark
|